Frank & Eileen

Open 3 Shape Dongle CEREC

Description: I am not real familiar with the dongle"s uses. Below is from the dongle's PDF. I have sold multiple units of this dongle and have had no problems. I will not accept returns and you should not purchase if you have any expectation of returning the item for any reason. I am not selling the item to be trialed with or tested. Again, the information listed comes directly from the item's PDF. Sold "AS IS." Open 3 Shape Dongle CEREC Dongle allows you to accept STL files into the Cerec software and export those files to the mill. Search on Google - 3 shape Cerec - pdf New Options with the OPEN 3Shape Interface Right now the OPEN 3Shape Interface allows you to import 3Shape scan data into the inLab or CEREC software (V3.65 or higher). Sirona and 3Shape agreed to add an additional function: Scans of Sirona scan devices can be transferred into the 3Shape software where the design is carried out. The completed design can be manufactured on the normal manufacturing equipment. Sirona Scanners could be either inEos Blue or CEREC AC (Bluecam). Intraoral scan data can be exported only when the scan has been transferred via the CEREC Connect portal into the inLab 3D Software (V3.86). Scans of Scanbodies in order to transfer implant data are currently not supported. The following data is transferred:  Model data of preparation and antagonist  Patients data  Toothnumbers of interest  Desired type of restoration (crown, bridge, …) System Requirements Sirona:  Compatible devices are:  inEos Blue  CEREC AC (Bluecam)  inLab V3.86 (or higher) is installed  OPEN 3Shape Interface (REF 6307735) is attached to the inLab PC 3Shape:  DentalSystem2010 Version 2.6.9.6 or higher  Sirona Export/Import Interface „*.3si/*.3se“ is activated Export from the Sirona inLab Software Perform the following steps to create and export the scan data: 1. Create order Make up a new order and fill in all the required information as usual. Take the images from preparation, antagonist and bite registry or as a buccal scan as needed. Let the software calculate the model and use “correct optical impression” if required. a. CEREC Connect order When you received an order via CEREC Connect load this case into the inLab software. By clicking the green “next” button you get into the portal where you can confirm your order. 2. Export scan The model is then exported as follows:  Choose “restoration / export…” in the menu bar: In the pop up window you can define:  where the scanfile is saved,  its name and  *.3se as file format (available only if OPEN 3Shape Interface is attached to an USB port) This „Scandata.3se“ file can now be opened with 3Shape DentalSystem 2010. Sirona Dental Systems GmbH, 12.04.2011 Import into 3Shape Dental System Perform the following steps to import the Sirona scan: 1. Import Sirona scan (3SE file) Right click in the main window and select Advanced -> Import. Then select Sirona Cerec & Inlab Import and browse the 3se file e.g. “Scandata.3se”. 2. Validate order Validate if the order is correct. Often the order information is not created properly by the Dentist. Check in particular indications and materials. Modify the order if needed. Notice the “Browse to Scan” button can be used to preview the scans to determine the tooth numbers. Sirona Dental Systems GmbH, 12.04.2011 3. Prepare Sirona Scan for design Double click on the order in the DentalManager to proceed with the preparation of the Sirona scan. Follow the instructions to trim the scan and virtually ditch the preparations. Sirona Dental Systems GmbH, 12.04.2011 Note in case of errors during preparation please try to reposition the cutting curves on the surface. 4. Design Lab Model (optional) In additional to the preparing the scan it is possible to complete a full lab model design for manufacturing on relevant equipment. Note it requires the Model Builder add-on module. 5. Start CAD design After completing the preparation the CAD design can be started and performed as normal.

Price: 499 USD

Location: Oak Ridge, Tennessee

End Time: 2023-09-12T10:19:54.000Z

Shipping Cost: 0 USD

Product Images

Open 3 Shape Dongle CERECOpen 3 Shape Dongle CEREC

Item Specifics

All returns accepted: ReturnsNotAccepted

Non-Domestic Product: No

Country of Manufacture: Germany

Model: 3 Shape

Modified Item: No

Country/Region of Manufacture: Germany

Custom Bundle: No

MPN: 1032B21526J27

Brand: Sirona Cerec

Recommended

NEW CEREC Tank Milling Filter Primemill  Sirona Dental 6387067 D3439
NEW CEREC Tank Milling Filter Primemill Sirona Dental 6387067 D3439

$35.00

View Details
Camera Cable Sirona Cerec OMNICAM OMNI CAM 6351022
Camera Cable Sirona Cerec OMNICAM OMNI CAM 6351022

$229.95

View Details
CEREC Omnicam Upgrade 5.2 PC - Fastest Omnicam  (intel i9!!)
CEREC Omnicam Upgrade 5.2 PC - Fastest Omnicam (intel i9!!)

$2650.00

View Details
Sirona Cerec Primescan External Camera Cable
Sirona Cerec Primescan External Camera Cable

$175.00

View Details
Sirona CEREC MC XL Dental Milling Machine for CAD/CAM Dentistry
Sirona CEREC MC XL Dental Milling Machine for CAD/CAM Dentistry

$5500.00

View Details
Dentsply Sirona - CEREC / inlab - ScanPost - REF 6544378 NEW SEALED
Dentsply Sirona - CEREC / inlab - ScanPost - REF 6544378 NEW SEALED

$17.85

View Details
2012 Sirona CEREC MC XL 2-Motor Wet Mill with 616 Mills (123952)
2012 Sirona CEREC MC XL 2-Motor Wet Mill with 616 Mills (123952)

$12995.00

View Details
Dentsply Sirona CEREC Primescan Dental Intraoral Scanner for CAD/CAM Dentistry
Dentsply Sirona CEREC Primescan Dental Intraoral Scanner for CAD/CAM Dentistry

$15750.00

View Details
(2) Dentsply Sirona Diamond 1.2 CS For Cerec prime mill
(2) Dentsply Sirona Diamond 1.2 CS For Cerec prime mill

$400.00

View Details
2017 Omnicam v3.2.2+ Cerec sw5.2.9 / Connect 5.2.4/ exp stl files
2017 Omnicam v3.2.2+ Cerec sw5.2.9 / Connect 5.2.4/ exp stl files

$2999.00

View Details