Frank & Eileen

Fluke 1587/MDT FC Advanced Motor and Drive Troubleshooting Kit

Description: Fluke 1587/MDT FC Advanced Motor and Drive Troubleshooting Kit Model: 1587/MDT FC | Order No:1587/MDTFC Ideal for troubleshooting and preventative maintenance, this insulation multimeter comes in a compact, handheld design, and features True RMS capabilities. Additionally, this kit comes supplied with the i400 current clamp and 9040 phase rotation indicator. Brand: Fluke Model: 1587/MDT FC Order No: 1587/MDTFC Condition: NEW Description Fluke 1587/MDT FC Advanced Motor and Drive Troubleshooting Kit Fluke 1587FC Offers The high-performance 2-in-1 insulation digital multimeter This insulation multimeter is the combination of a digital insulation tester that comes supplied with a full-featured, True RMS digital multimeter in a single compact, handheld unit, which enables maximum versatility for troubleshooting and preventative maintenance. FeaturesPI/DAR timed ratio testsLive circuit detection prevents insulation test if voltage >30 V is detected for added user protectionVFD low-pass filter for accurate motor drive measurementsAuto-discharge of capacitive voltage for added user protectionInsulation test of 0.01 MΩ to 2 GΩInsulation test voltages of 50, 100, 250, 500 V for many applicationsAC/DC voltage, DC millivolts, AC/DC milliamps, resistance (Ω), continuityCapacitance, diode test, temperature, Min/Max, frequency (Hz)Auto power off to save battery powerCAT III 1000 V, CAT IV 600 V measurement categoryLarge display with backlightSafety first. Keep yourself out of harm's way by monitoring your test measurements remotelyProve your job is done right by quickly seeing and sharing measurement results wirelessly with your smartphoneQuickly find problems by saving and comparing measurements over time on a wireless device Keep yourself safe. Find hidden problems faster. Put the paperwork down. Fluke Connect and this insulation multimeter helps you identify tough problems, fix, and wirelessly communicate your work quickly and easily - all at a safe distance. Add diagnostics with Fluke Connect Fluke Connect is enabled so you can download the free application to your smartphone and gain additional functions, including:Safety first. Keep yourself out of harm's way by monitoring your test measurements remotelyProve your job is done right by quickly seeing and sharing measurement results wirelessly with your smartphoneQuickly find problems by saving and comparing measurements over time on a wireless devicePI/DAR timed ratio tests with TrendIt™ graphs to identify moisture and contaminated insulation problems fasterMemory storage through Fluke Connect that saves measurements to your phone or the cloud and eliminates the need to write down results. Reduces errors and saves data for historical tracking over timeTemperature compensation to establish accurate baselines and relevant historical comparisonsHistorical tracking and trending of assets to identify insulation degradation over time and allow real-time decisions to be made in the field with Fluke Connect® Assets (sold separately)Provides memory storage through Fluke Connect Measurements to eliminate the need to write down resultsIncludes live circuit detection to prevent insulation test if voltage >30 V is detectedProvides automated temperature compensation to establish accurate baselinesIncorporates VFD low-pass filter for accurate variable frequency motor drive measurementsIncludes auto-discharge of capacitive voltage for added user protectionMeasures ac/dc voltage, dc millivolts, ac/dc milliamps, resistance, and continuityIncludes capacitance, diode test, temperature, min/max, frequency measurements and insulation test smoothing reading Fluke i400 AC Current Clamp FeaturesCompanion to your DMM to measure up to 400 A AC1mA/Amp output guarantees easy reading on you meterOnly current clamp available with a CAT IV 600 V / CAT III 1000 V safety ratingSpecially designed to offer maximum utility in a very compact shape Fluke 9040 Phase Rotation Indicator Features3 phase indicationIndication of phase rotationClear LCD displayNo battery requiredelementExists('bonus-content/fluke-1503')) {echo $this->element('bonus-content/fluke-1503');}?>elementExists('Blog/fluke-using-fluke-thermal-imaging-to-troubleshoot-motors-and-drives')){ echo $this->element('Blog/fluke-using-fluke-thermal-imaging-to-troubleshoot-motors-and-drives');}?> Included 1587 FC Insulation Multimeter i400 Current Clamp 9040 Phase Rotation Indicator Remote ProbeTest LeadsAlligator ClipsK-Type ThermocoupleCarrying CaseUser Documentation Specifications AC Voltage MeasurementsRange600 mV 6 V 60 V 600 V 1000 VResolution0.1 mV 0.001 V 0.01 V 0.1 V 1 V50 to 60 Hz ±(% of Rdg + counts)±(1% + 3) ±(1% + 3) ±(1% + 3) ±(1% + 3) ±(2% + 3)60 to 5000 Hz ±(% of Rdg + counts)±(2% + 3) ±(2% + 3) ±(2% + 3) ±(2% + 3)1 ±(2% + 3)1Low-Pass Filter VoltageRange600 mV 6 V 60 V 600 V 1000 VResolution0.1 mV 0.001 V 0.01 V 0.1 V 1 V50 to 60 Hz ±(% of Rdg + counts)±(1% + 3) ±(1% + 3) ±(1% + 3) ±(1% + 3) ±(2% + 3)60 to 400 Hz ±(% of Rdg + counts)±(2% + 3) - (6% - 3) ±(2% + 3) - (6% - 3) ±(2% + 3) - (6% - 3) ±(2% + 3) - (6% - 3) ±(2% + 3) - (6% - 3)DC Voltage MeasurementRange6 V dc 60 V dc 600 V dc 1000 V dcResolution0.001 V 0.01 V 0.1 V 1 VAccuracy ±(% of Rdg + Counts)±(0.09% + 2) ±(0.09% + 2) ±(0.09% + 2) ±(0.09% + 2)Input Impedance10 MΩ (nominal), Nominal Mode Rejection Ratio>60 dB at 50 or 60 HzCommon Mode Rejection Ratio>120 dB at dc, 50 or 60 Hz (1 k unbalance)DC Millivolts MeasurementRange600 mVdcResolution0.1 mVAccuracy ±(% of Rdg + Counts)±(0.1 + 1)DC and AC Current MeasurementRange400 mAResolution0.1 mAAccuracy ±(% of Rdg+Counts)±(1.5% + 2)1Burden Voltage (Typical)2 mV/mARange60 mAResolution0.01 mAAccuracy ±(% of Rdg+Counts)±(1.5% + 2)1Burden Voltage (Typical)2 mV/mADCRange400 mAResolution0.1 mAAccuracy ±(% of Rdg+Counts)±(0.2% + 2)Burden Voltage (Typical)2 mV/mARange60 mAResolution0.01 mAAccuracy ±(% of Rdg+Counts)±(0.2% + 2)Burden Voltage (Typical)2 mV/mAOverload600 mA for 2 minutes maximumFuse Protection for mA Input0.44 mA, 1000 V, IR 10 kAAC ConversionInputs are ac-coupled and calibrated to the rms value of sine wave inputOhms MeasurementRange600 Ω 6 kΩ 60 kΩ 600 kΩ 6 MΩ 50 MΩResolution0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩAccuracy +(% of Rdg+Counts)1±(0.9% + 2) ±(0.9% + 2) ±(0.9% + 2) ±(0.9% + 2) ±(0.9% + 2) ±(1.5% + 3)Overload Protection 1000 rms or dcOpen Circuit Test VoltageShort Circuit CurrentDiode TestDiode Test IndicationDisplay voltage drop: 0.6 V at1.0 mA nominal test currentAccuracy±(2% + 3)Continuity TestContinuity IndicationContinuous audible tone for testresistance below 25 Ω and off above 100 Ω Maximum reading: 1000 ΩOpen Circuit VoltageShort Circuit Current1.0 mA typicalOverload Protection1000 V rmsResponse Time>1 m secFrequency MeasurementRange99.99 Hz 999.9 Hz 9.999 kHz 99.99 kHzResolution0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHzAccuracy ±(% of Rdg+Counts)±(0.1% + 1) ±(0.1% + 1) ±(0.1% + 1) ±(0.1% + 1)Frequency Counter Sensitivity600.0 mV acV ac Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 100.0 mV V ac Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 150.0 mV DC Trigger Levels¹ to 20 kHz2: NA6.0 VV ac Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 1.0 V V ac Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 1.5 V DC Trigger Levels¹ to 20 kHz2: -400.0 mV and 2.5 V60.0 VV ac Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 10.0 V V ac Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 36.0 V DC Trigger Levels¹ to 20 kHz2: 1.2 V and 4.0 V600.0 VV ac Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 100.0 V V ac Sensitivity (RMS Sine Wave)1 20 to 100 kHz: NA DC Trigger Levels¹ to 20 kHz2: 12.0 V and 40.0 V1000.0 VV ac Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 300.0 V V ac Sensitivity (RMS Sine Wave)1 20 to 100 kHz: NA DC Trigger Levels¹ to 20 kHz2: 12.0 V and 40.0 VCapacitanceRange1000 nF 10.00 µF 100.0 µF 9999 µFResolution1 nF 0.01 µF 0.1 µF 1 µFAccuracy ±(% of Rdg+Counts)±(1.2% + 2) ±(1.2% + 2) ±(1.2% ± 90 counts) ±(1.2% ± 90 counts)Temperature MeasurementRange-40 to 998°F (-40 to 537°C)Resolution0.1°F (0.1°C)Accuracy ±(% of Rdg+Counts)1±(1% + 10 counts) ±(1% + 18 counts)Insulation SpecificationsMeasurement Range0.01 MΩ to 2 GΩTest Voltages50, 100, 250, 500, 1000 VTest Voltage Accuracy20%, 0%Short-Circuit Test Current1 mA nominalAuto DischargeDischarge time Live Circuit DetectionInhibit test if terminal voltage >30 V prior to initialization of testMaximum Capacitive LoadOperable with up to 1 µF loadOutput Voltage50 V (0% to +20%)Display range: 0.01 to 6.00 MΩ Resolution: 0.01 MΩ Test current: 1 mA at 50 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts) Display range: 6.0 to 50.0 MΩ Resolution: 0.1 MΩ Test current: 1 mA at 50 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts)100 V (0% to +20%)Display range: 0.01 to 6.00 MΩ Resolution: 0.01 MΩ Test current: 1 mA at 100 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts) Display range: 6.0 to 60.0 MΩ Resolution: 0.1 MΩ Test current: 1 mA at 100 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts) Display range: 6.0 to 100.0 MΩ Resolution: 0.1 MΩ Test current: 1 mA at 100 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts)250 V (0% to +20%)Display range: 0.1 to 60.0 MΩ Resolution: 0.1 MΩ Test current: 1 mA at 250 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) Display range: 60 to 250 MΩ Resolution: 1 MΩ Test current: 1 mA at 250 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)500 V (0% to +20%)Display range: 0.1 to 60.0 MΩ Resolution: 0.1 MΩ Test current: 1 mA at 500 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) Display range: 60 to 500 MΩ Resolution: 1 MΩ Test current: 1 mA at 250 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)1000 V (0% to +20%)Display range: 0.1 to 60.0 MΩ Resolution: 0.1 MΩ Test current: 1 mA at 1 MΩ Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) Display range: 60 to 600 MΩ Resolution: 1 MΩ Test current: 1 mA at 1 MΩ Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) Display range: 0.6 to 2.0 GΩ Resolution: 100 MΩ Test current: 1 mA at 1 MΩ Resistance accuracy ±(% of Rdg + Counts): ±(10% + 3 counts) Terms & Conditions Item Condition: Unless specified otherwise all products listed are Brand New in the original factory packaging and include a full factory warranty. Shipping: We currently only ship to U.S. buyers. We ship items within one or two business days from payment. We do not process shipments on weekends and holidays. Local pick up is not available. We only ship to addresses verifiable by either PayPal or credit card issuing bank. Please note that we cannot alter the address once a purchase is made. In the case of PayPal payment, we will ship orders when the payment is marked “Eligible” for PayPal Seller’s protection. *Shipping Rates are for Continental US, Please Contact us for other US Destinations Payment: Currently all payments must be made directly though PayPal Sales Tax: We are required to charge sales tax in North Carolina Return Policy: If for any reason you are not 100% satisfied with a product you receive from us, you may return the regular stock product within 30 days from the time of receipt, for a full refund or exchange of the product you purchased (less any shipping costs). Within this time, products may be returned; freight prepaid and must be in their original packaging and in resalable condition. Shipping errors, missing items or damages must be reported to us immediately (damages should be accompanied by a signed bill of lading acknowledging the damage). Items returned will be inspected for damage or misuse at which time they may be subject to restocking fees, other fees or refused, prior to the issuance of any credit.

Price: 1748.09 USD

Location: Wilmington, North Carolina

End Time: 2024-12-19T02:02:42.000Z

Shipping Cost: 0 USD

Product Images

Fluke 1587/MDT FC Advanced Motor and Drive Troubleshooting Kit

Item Specifics

Return shipping will be paid by: Seller

All returns accepted: Returns Accepted

Item must be returned within: 30 Days

Refund will be given as: Money back or replacement (buyer's choice)

Return policy details:

Brand: Fluke

MPN: 1587/MDT FC

Model: 1587/MDT FC

Recommended

Fluke 1AC-C2II VoltAlert Non-Contact Voltage Detector Pen Tester W/sound
Fluke 1AC-C2II VoltAlert Non-Contact Voltage Detector Pen Tester W/sound

$21.79

View Details
Fluke T5-600 Voltage Continuity and Current Electrical Tester #648227
Fluke T5-600 Voltage Continuity and Current Electrical Tester #648227

$134.99

View Details
Fluke 289 True RMS Multimeter  and  New Fluke Bag
Fluke 289 True RMS Multimeter and New Fluke Bag

$389.00

View Details
Fluke 1503 Digital Insulation Resistance Meter Megger 2000 MΩ Backlight CAT IV
Fluke 1503 Digital Insulation Resistance Meter Megger 2000 MΩ Backlight CAT IV

$249.98

View Details
Genuine Fluke TP220 SureGrip Test Probes for TL222/TL224 / Red & Black color
Genuine Fluke TP220 SureGrip Test Probes for TL222/TL224 / Red & Black color

$12.29

View Details
Fluke 51 II Single Input Digital Thermometer with 60Hz, LCD Display, Type K Bead
Fluke 51 II Single Input Digital Thermometer with 60Hz, LCD Display, Type K Bead

$275.99

View Details
Fluke 117/323 Electricians Combo Kit Digital Multimeter Clamp Meter
Fluke 117/323 Electricians Combo Kit Digital Multimeter Clamp Meter

$309.00

View Details
Fluke T150 VDE OR FLUKE T150 Two-pole Voltage and Continuity Electrical Tester/
Fluke T150 VDE OR FLUKE T150 Two-pole Voltage and Continuity Electrical Tester/

$42.78

View Details
Fluke 107 AC/DC 600v Digital Multimeter 2589556 1133
Fluke 107 AC/DC 600v Digital Multimeter 2589556 1133

$84.00

View Details
Fluke 301D AC/DC Clamp Meter 600A 600V Voltage Current Frequency Backlight
Fluke 301D AC/DC Clamp Meter 600A 600V Voltage Current Frequency Backlight

$142.66

View Details