Description: Low Temperature Cooling Liquid Circulator 6L Introduction DC series low temperature constant temperature tank is controlled by single chip microprocessor, self-tuning PID adjustment, imported temperature sensor temperature measurement, high temperature control accuracy, low volatility; high quality famous brand compressor (some models are all imported compressors or compressors), high refrigeration efficiency, fast cooling and low noise. The instrument is stable and reliable, and the operation is convenient and safe. It is widely used in the fields of biological engineering, medicine, food, chemical industry, metallurgy, chemical analysis, oil and the like, and provides a constant field source with high precision, controlled and uniform temperature for users, and is an ideal constant temperature device for research institutes, colleges and universities, factory laboratories and quality inspection departments. Features1. The machine adopts microcomputer based temperature control. High accuracy of temperature control. 2. Intelligent digital system can correct the deviation of the temperature measurement, which make the digital resolution 0.1℃. 3. The refrigeration system has over-heating and over-current multiple protective function. 4. The machine has intelligent instrument control, which easy to operate and of high temperature stability. It is also has alarm function when the temperature reach the upper and lower limitation. 5. Equipped with fully efficient anti-interference compressor. 6. Cooling rate is faster than similar products, lower noise, lower vibration.Parameters ModelDC0506W Voltage110VPower1500WVolume6Ltemperature fluctuation±0.03 ℃(Water or pure ethanol)Temperature range-5℃-100℃resolution ratio0.01 ℃Opening Size145×145×150mm(long and wide and deep)pumping flow8 L/minPump circulation modeoutput loopInstruction 1.Remove the package, do a good job of cleaning, put on the solid worktable. 2.A sufficient amount of liquid medium is added to the tank so that the distance between the liquid level of the medium and the working table is less than 3 cm. If the amount of liquid poured into the tank is too small, the low liquid level prompt flashes when turned on, accompanied by alarm sound. 3.Connecting the circulating pump to the water outlet pipe. (1) When the circulating pump does not need external circulation, just use the hose to connect the inlet and outlet. (2)When the circulating pump needs constant temperature liquid external circulation, two hoses are used to connect the "outlet" tube with the inlet of the external experimental container, and the "inlet" tube and the outlet pipe of the external experimental container can be connected. Note: be sure to connect the inlet pipe with the outlet pipe before turning on the power supply. 4. Turn on the power supply and turn on the power switch of the rear cover. At this time, the liquid crystal display screen will display all the symbols to enter the self-test, and the temperature input range will be displayed after 3 seconds (upper row: PV is displayed as the upper limit value of the input temperature, lower row: SV is displayed as the lower limit value of the input temperature), and after the self-test passes, the PV will be displayed as the actual temperature of the liquid in the slot, and the SV will be displayed as the temperature set last time. 5. Set temperature. It is suggested that the refrigeration opening logic should be satisfied: both PV and SVvalues are less than 41 ℃ and the refrigeration function is turned on more than 5 minutes before the compressor is shut down last time, on the contrary, the refrigeration output is turned off.Environmental requirements1. The thermostatic bath shall be placed on a solid working table. 2. No vibration and no harmful gas. 3. Ambient temperature should be less than 30°C and relatively stable, cannot be high and low, affect the temperature control accuracy. 4. The ambient humidity should be less than 80% and the humidity is too high. When the constant temperature tank is working at low temperature, the compressor may dewing.Precautions for Use1. Before use, it must be confirmed that the liquid medium has been added to the tank body, and the distance between the liquid level of the medium and the working table should be less than 3 cm, otherwise the heater may dry burn and damage when electrified.。 2. The selection of liquid media in the tank shall conform to the following principles: ⑴When the working temperature is lower than 5 ℃, absolute ethyl alcohol or ethylene glycol is used for the liquid medium. ⑵When the working temperature is 5 ℃ ~95 ℃, water is generally used in liquid medium. ⑶When the working temperature is between 95 and 100 ℃ , a 15% aqueous glycerol solution can be used for the liquid medium. Note: The operating temperature here is the temperature to which the liquid medium in the tank is to be reached; 3. Power supply:110V, the power of the power supply shall be greater than the total power of the instrument, and the power supply must have good "ground" device; 4. Because the refrigeration compressor works continuously (refrigerator, air conditioning is intermittent), it needs to be shut down for a day after a long period of continuous work (such as about 5 days). 5. The instrument should be placed in a dry and ventilated place, and there are no obstacles in the 300mm around the instrument. 6. When the working temperature of the thermostatic bath is lower or higher, care should be taken not to open the upper cover, and do not enter the tank to prevent frostbite or scald. 7. After the use, all the switches are put in the closed state and the power is cut off. 8. The instrument should do a good job of regular cleaning and keep the working table and operation panel clean and tidy. 9. Pay attention to the level of the liquid level in the observation tank. When the liquid level is too low, the liquid medium shall be added in time. DisplayItem Number:020462You can make order with no worry. Any concerns just feel free to let us know, we'll reply in 24 hours in normal condition. Handling Time: Shipping is usually made in 1-3 business days after payments cleared. Orders are processed from Monday-Friday; Not on the weekends & public holidays. Warranty: 6 months' warranty for the machines, not for the consumables. We stand behind our products all the item, so even if your warranty period has expired, you can still seek for service or technical support from us with low cost.Shipping & Handling DetailsDefault Shipping Cost or Free Shipping Information: ▲ Default shipping cost or free shipping service is only for the lower 48 United States by UPS Ground or USPS. Other areas or needs other shipping ways, please contact us. ▲ Buyers from Guam, Puerto Rico, Virgin Islands, American Samoa, Alaska, Hawaii, PO Boxes, APO/FPO addresses or other countries/areas, there WILL be extra shipping costs, please contact us for more detailed information. ▲ Please make sure your address is valid for both UPS and USPS services. Any costs incurred because of incorrect or undeliverable address should be undertaken by buyer.Handling Time: Shipping is usually made in 1-3 business days after payments cleared. Orders are processed from Monday-Friday; Not on the weekends & public holidays.Sales tax / Customs duties: Any sales taxes or Customs duties are not included. If came out, they must be undertaken by the buyer. Sales Tax of 8% will be applied for orders shipped within the state of California.Damage In Shipping: Email or call us First! We will work with you to get the case resolved in the fastest method.Return / RefundIf you are not 100% happy with your purchase, please contact Us. Please don't directly opened a request or case without informing us, or else, we will do some discounts on the warranty and other sales-services later on. Hope for your understanding.Returns & Exchanges▲ All returns must be made within 14 days of delivery date. Items must be in new, unused condition, with all original materials included with the shipment. A partial refund may be applied for opened or damaged items, depending on the condition. ▲ Items returned under the buyer’s remorse: The return shipping fee must be covered by the buyer; The original shipping cost will also be deducted from the refund. 15% restocking fee of the items purchase price will be charged. ▲ Returns that are the result of our seller's error: Buyer will receive a full refund of the item as well as shipping charges ▲ All returns require a RA (Return Authorization) number that will be given by our seller. Please contact with us at first for more details.Defective & Damaged Products ▲ If product was received damaged or not as described, please send us some pictures or videos, so we could well understand your problem, then solve them for you ASAP. Besides, it's much helpful for us to claim with UPS, remind our related department to pay much more attention to packaging later on. Hope for your understanding. ▲ Replacement or refund of defective or damaged products can only be returned in exchange for the exact same product, or else, the purchase price will be refunded back to your original payment method. ▲ If an item is received damaged, customer service must be contacted within 7 days of receiving your item. All returns require a RA (Return Authorization) number as above.PaymenteCheck Issues: Payments via eCheck do not clear immediately. Usually you will wait 5-7 days after checkout for it to clear. Then we will arrange shipments for you.Warranty & Feedback▲ 6 months' warranty for the machines, not for the consumables. We stand behind our products all the item, so even if your warranty period has expired, you can still seek for service or technical support from us with low cost. ▲ Any warranty shipping cost to us is responsible by buyer. ▲ Any shipping cost to buyer is responsible by the seller. ▲ We committee to the customer satisfaction and want to bring you the best purchase experience. If there is any problems, please contact us ASAP. If not, please leave us a positive feedback as it's very important for us. Thanks very much.
Price: 973.56 USD
Location: Rancho Cucamonga, California
End Time: 2025-01-06T05:10:16.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Brand: PreAsion
Product: Recirculating Chiller
MPN: 020462